MIB REFERENCE

RADWIN BROADBAND WIRELESS PRODUCTS

Release 4.9.35 Cat.No. DO0168170/0.8

RADWIN

MMMM

Table of Contents

CONTFONM MOEN OG Fi vtsiis seced ctxasccuees assceesees coteaxannsdesauena veesss earita aceon viissreeea mache meaa ee

A 2. Private MIB: ParanMmetels: vacesssccccesceccavsscecsssde scoasncexesanceeen okanea sinc tiaeivesteowsdaecasecarsvanvaesssseimacwectanea D PB MCAD Siseycucatesticeccet csauctencseueaceeusva¢aveseaeccctuscstenesanederetvavaaateatetuceessdaccesnetdvusssiactueseatecesesveseas

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35 Page-i

Chapter 1: Introduction

1.1 About the MIB

The RADWIN MIB is a set of APIs that enables external applications to control RADWIN equipment.

The MIB is divided into public and a private API groups: e Public: RFC-1213 (MIB Il) variables, RFC-1214 (MIB II) System and interfaces sections e =Private: Controlled by RADWIN and supplements the public group.

This appendix describes the public and private MIB used by RADWIN.

1.2 Terminology

The following terms are used in this document.

CPE Customer Premises Equipment. Used in the same manner as HSU. MIB Management Information Base

API Application Programming Interface

SNMP Simple Network Management Protocol

In addition, the MIB uses internally, the older notions of Local site and Remote site where this manual would use site A and site B.

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35 Page-1

Chapter 2: Interface API

2.1 Control Method

The RADWIN Manager application provides all the means to configure and monitor a RADWIN Broadband Wireless Products link, communicating with the SNMP agent in each ODU. Each SNMP agent contains data on each of the PoEs and ODUs in the link. Both agents communicate with each other over the air using a proprietary protocol.

Each ODU has a single MAC address and a single IP address.

Note

To control and configure the device using the MIB, adhere to the following rules:

The connection for control and configuration is to the local site, over any SNMP/UDP/IP network.

All Parameters should be consistent between both of the ODUs. Note that inconsistency of air parameters can break the air connection. To correct air parameters inconsistency you must reconfigure each of the ODUs.

Common practice is to configure the remote site first and then to configure the local site.

For some of the configuration parameters additional action must be taken before the new value is loaded. Please refer to the operation in the parameters description.

Some of the MIB parameters values are product dependent. It is strongly recommend using the RADWIN Manager Application for changing these values. Setting wrong values may cause indeterminate results.

2.2 Community String

To control a link, all SNMP requests should go to the local site IP address.

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35 Page-2

Chapter 3: Private MIB Structure

The sections in the private RADWIN MIB and its location in the MIB tree are shown in Figure 1 below:

-~-§QB winlink 1000GeneralTrapSeverity

Figure 1: Top Level Sections of the private MIB

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35 Page-3

Private MIB Structure Private MIB Structure

The products MIB section contains the definition of the Object IDs for the two types of units, Integrated Antenna (where applicable) and Connectorized (referred in the MIB as external antenna) and GSU (where applicable):

“i :

- )) winlink1000Family - |) radwin2000Family

fT)

“§@y oduGSUExternalAntenna =} )) radwinSOOOHBSFamily Gi» J) oduHBs ~~ OdUHBSIntegratedAntenna oy OdUHBSExternalAntenna =} J) radwin5000HSUFamily 5 mY) oduHSU ~@@ oduHSUIntegratedAntenna §@y odUHSUExternalAntenna GH} radwin6000Family ea radwinWiFiAPFamily 4) J) winlink1000

oH

Figure 2: Product MIB

The GpsSynchronizerFamily MIB defines the GSU.

The general MIB include a single generic parameter that is used by all traps as a trap description parameter.

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35

radio

Page 4

Chapter 4: MIB Parameters

This section describes the MIB parameters. The MIB parameters use the following naming convention:

<winlink1000><Section 1>...<Section n><Parameter Name>

For each of the configuration and control parameters (parameters with read-write access), the “Description” column describes when the new value is effective. It is recommended that you perform the appropriate action to make the values affective immediately after any change. Where a change is required on both sides of the link, it is recommended that you change both sides of the link first and then perform the action.

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35 Page-5

Supported Variables from the RFC 1213 MIB

MIB Parameters

4.1 Supported Variables from the RFC 1213

MIB

Table 7-1: Supported RFC 1213 Variables (Sheet 1 of 3)

Name

OID

Type

Description

ifNumber

1.3.6.1.2.1.2.1.

Integer

3 | Access

The number of network interfaces (regardless

of their current state) present on this system.

iflndex .1.3.6.1.2.1.2.2.1.1.x Integer RO A unique value for each interface.Its value ranges between 1 and the value of ifNumber.The value for each interface must remain constant at least from one re- initialization of the entity's network management system to the next re- initialization.

ifDescr .1.3.6.1.2.1.2.2.1.2 DisplayString RO A textual string containing information about the interface.This string should include the name of the manufacturer, the product name

and the version of the hardware interface.

iffype .1.3.6.1.2.1.2.2.1.3 Integer RO The type of interface, distinguished according to the physical/link protocol(s) immediately ‘pelow' the network layer in the protocol stack.

ifMtu 1.3.6.1.2.1.2.2.1.4. Integer RO The size of the largest datagram which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface.

ifSpeed .1.3.6.1.2.1.2.2.1.5 Gauge RO An estimate of the interface's current bandwidth in bits per second.For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should ontain the nominal bandwidth.

ifPhysAddress .1.3.6.1.2.1.2.2.1.6 Phys-Address RO The interface's address at the protocol layer immediately ‘below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero

length.

ifAdminStatus .1.3.6.1.2.1.2.2.1.7 Integer RW The desired state of the interface. The testing(3) state indicates that no operational

packets can be passed.

ifOperStatus .1.3.6.1.2.1.2.2.1.8 Integer RO The current operational state of the interface. The testing(3) state indicates that no

operational packets can be passed.

1.3.6.1.2.1.2.2.1.9. Counter RO The value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re- initialization of the local network management subsystem, then this object contains a zero value.

ifLastChange

iflnOctets .1.3.6.1.2.1.2.2.1.10.x Counter RO The total number of octets received on the interface, including framing characters.

iflnUcastPkts .1.3.6.1.2.1.2.2.1.11.x Counter RO The number of subnetwork-unicast packets

delivered to a higher-layer protocol.

iflnNUcastPkts .1.3.6.1.2.1.2.2.1.12.x Counter RO The number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast) packets

delivered to a higher-layer protocol.

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35 Page 6

Supported Variables from the RFC 1213 MIB MIB Parameters

Table 7-1: Supported RFC 1213 Variables (Sheet 2 of 3) Name OID Type

Description

3 | Access

iflnDiscards 1.3.6.1.2.1.2.2.1.13.x Counter The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet

could be to free up buffer space.

iflnErrors .1.3.6.1.2.1.2.2.1.14.x Counter RO The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.

iflnUnknownProtos 1.3.6.1.2.1.2.2.1.15.x Counter RO The number of packets received via the interface which were discarded because of an unknown or unsupported protocol.

ifOutOctets .1.3.6.1.2.1.2.2.1.16.x Counter RO The total number of octets transmitted out of the interface, including framing characters.

ifOutUcastPkts .1.3.6.1.2.1.2.2.1.17.x Counter RO The total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent.

ifOutNUcastPkts .1.3.6.1.2.1.2.2.1.18.x Counter RO The total number of packets that higher-level protocols requested be transmitted to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent.

ifOutDiscards 1.3.6.1.2.1.2.2.1.19.x Counter RO The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space.

ifOutErrors 1.3.6.1.2.1.2.2.1.20.x Counter RO The number of outbound packets that could not be transmitted because of errors.

ifOutQLen 1.3.6.1.2.1.2.2.1.21.x Counter RO The length of the output packet queue (in packets).

ifSpecific 1.3.6.1.2.1.2.2.1.22 OID RO A reference to MIB definitions specific to the

particular media being used to realize the interface. For example, if the interface is realized by an ethernet, then the value of this object refers to a document defining objects specific to ethernet. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.

sysDescr 1.3.6.1.2.1.1.1. OctetString RO A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software.

sysObjectID 1.3.6.1.2.1.1.2. OID RO The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining ‘what kind of box' is being managed. For example, if vendor ‘Flintstones,Inc.' was assigned the subtree 1.3.6.1.4.1.424242, it could assign the identifier 1.3.6.1.4.1.424242.1.1 to its ‘Fred Router'

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35 Page 7

Supported Variables from the RFC 1213 MIB MIB Parameters

Table 7-1: Supported RFC 1213 Variables (Sheet 3 of 3) Name OID Type

Description

3 | Access

sysUpTime 1.3.6.1.2.1.1.3. Counter Thetime(inhundredths of asecond) sincethe network management portion of the system

was last re-initialized.

sysContact 1.3.6.1.2.1.1.4 OctetString RW The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.

sysName 1.3.6.1.2.1.1.5 OctetString RW _ | An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.

sysLocation 1.3.6.1.2.1.1.6. OctetString RW _ | The physical location of this node (e.g., ‘telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.

sysServices 1.3.6.1.2.1.1.7. Integer RO A value which indicates the set of services that this entity may potentially offer. The value is a sum. This sum initially takes the value zero. Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L- 1) is added to the sum. For example, a node which performs only routing functions would have a value of 4 (24(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (24(4-1) + 24(7-1)).

RADWIN Broadband Wireless Products MIB Reference Release 4.9.35 Page 8

Private MIB Parameters

4.2 Private MIB Parameters

4.2.1 HBS

Table 8: HBS Private MIB Parameters (Sheet 1 of 43)

MIB Parameters

orFreqBandld

Name OID Type o Description 0 °o 4 winlink1000GeneralCookie RW_| Reserved for the Manager application provided with the product used for saving user preferences affecting ODU operation. winlink1000GeneralEcChangesCounte RO | This counter is initialized to O after a device reset r and is incremented upon each element constant write operation via SNMP or Telnet. winlink1000GeneralSNMPSupport RW_ | Enable/Disable SNMP protocols winlink1000GeneralSSHSupport RW | Enable/Disable SSH protocols winlink1000GeneralTelnetSupport RW _ | Enable/Disable Telnet protocol. Mandatory Disabled - No option to enable the feature. Mandatory Enabled - No option to disable the feature. winlink1000GeneralTrapDescription RO | Trap's Description. Used for Trap parameters. winlink1000GeneralTrapSeverity RO | Trap's Severity. Used for Trap parameters. winlink1000GeneralWISupport RW_ | Enable/Disable Web Interface protocol. Mandatory Disabled - No option to enable the feature. Mandatory Enabled - No option to disable the feature. Secured Only Enabled - enable select HTTPS only. Secured Disabled - disable HTTPS. Secured all Enabled - enable select HTTP and HTTPS. winlink100OHbsAdminBackwardsSup RW_| Backward support indication. port winlink1000HbsAdminInstallationCon RW_ | Installation Confirmation required for Radius mode. firmationRequired 1- true 2- false winlink100O0OHbsAdminRemoteTrapGe RW_ | HBS generation of remote traps (1=Off 2=On) nerationMode winlink1OOOHbsAirAtpcEnable RW_ | ATPC mode (off static or dynamic) status winlink1OOOHbsAirAtpcMaxAllowedR RO | Max allowed rate (will be 207 for N products and ate 209 for AC products) winlink1OOOHbsAirAtpcMaxAllowedR N/A | Atpc Target Rss Per Rate table entry. INDEX { ateEntry winlink1OOOHbsAirAtpcTargetRSSPerRatelndex } winlink1OOOHbsAirAtpcTargetMCS RW _ | targetRate for ATPC operation (100-309) winlink1OOO0HbsAirAtpcTargetRSSPerR RO | Atpc Target Rss Per Rate value. ate winlink1O00HbsAirAtpcTargetRSSPerR RO | Atpc Target Rss Per Rate Index. atelndex winlink1O00HbsAirAtpcTargetRSSPerR N/A | Table of Atpc Target Rss Per Rate. ateTable winlink1OO0OHbsAirAvailResourcesDL RO | This parameter holds the number of available DL Resources (not in use) in the air interface. winlink1OOO0HbsAirAvailResourcesUL RO | This parameter holds the number of available UL Resources (not in use) in the air interface. winlink1OOOHbsAirAvailTimeSlots RO | This parameter holds the number of available time slots (not in use) in the air interface. winlink1OO0OHbsAirAvailTimeSlotsUp RO | This parameter holds the number of available UL time slots (not in use) in the air interface. winlink1OOOHbsAirComboSwitchSect RW_ | Switch Frequency band for the whole sector.

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 9

HBS

Table 8: HBS Private MIB Parameters (Sheet 2 of 43)

MIB Parameters

cesUL

Name OID Type 3 Description oO oO 4 winlink1OOOHbsAirComboSwitchSect RW_ | Switch Frequency band for the whole sector orFreqBandldStr overriding some of the Combo parameters. winlink1O000HbsAirCompressedMon RO | Holds HBS monitor data in compressed format: HBS Traffic Monitor In Bytes(4) Out Bytes(4) In Frames(4) Out Frames(4) HBS State (1) HBS Freq (4) Number of Links (2) EC Change Counter (4) Current Ratio (2) Total Air Frames (4) HBS Rx Rate in Kbps (4) HBS Tx Rate in Kbps (4) HBS Rx Rate in Fps (4) HBS Tx Rate in Fps (4) HBS Set Mode (1) HBS LAN 1 Rx Rate in Kbps (4) HBS LAN 1 Tx Rate in Kbps (4) HBS LAN 1 Rx Rate in Fps (4) HBS LAN 1 Tx Rate in Fps (4) HBS LAN 2 Rx Rate in Kbps (4) HBS LAN 2 Tx Rate in Kbps (4) HBS LAN 2 Rx Rate in Fps (4) HBS LAN 2 Tx Rate in Fps (4) SyncE Performance (1) Max Available BE HSUs (1). winlink1000HbsAirCompressedMonS RO | One string that holds the 4 Utilization per Sector ec values: DownUtil (2 bytes) UpUtil (2 bytes) DowntTraffic (4 bytes) UpTraffic (4 bytes). winlink1O0OOHbsAirConfAutoRealignm RW_ | Configuration Parameters For Auto Realignment. entConfiguration winlink100OHbsAirConfBeaconRssSyn RW_ | Interval over which the RSS value is below the cLossInterval threshold. winlink1OOOHbsAirConfBeaconRssSyn RW_ |RSS Threshold For Syncloss In Mobile Units cLossThreshold winlink1OOOHbsAirConfBEPercentage RW_ | BE allocation percentage from the total resources (DownLink|UpLink]). winlink1000HbsAirConfChanges RO | 16 characters that represent 16 HSUs. Each time a configuration is been changed increment the relevant character. winlink1O00HbsAirConfDelaySensitivi RW _| Delay Sensitivity to specific HSU. ty winlink1OOOHbsAirConfDesiredRateln RW_ | The rate index of both sides of the link to this HSU. dex winlink1OOOHbsAirConfDownMir RW_ | Downlink MIR towards specific HSU in units of kbps. winlink1OOOHbsAirConfDualAntTxMo RW _| Transmission type when using Dual Antenna on de both link's sides. spatial Multiplexing Diversity (using a single spatial stream) and Auto Selection (OMS control). winlink1O0OHbsAirConfEntry N/A | HSUs configuration table entry. INDEX { winlink1000HbsAirConflndex } winlink1OOOHbsAirConfGeoLocation RW_ | Geographic device location in format: latitude longitude. winlink1OOOHbsAirConfHsuLevel RW_ | HSU level (1 .. 4) winlink1OOOHbsAirConfHsuLocation RW_ | HSU location. winlink1000HbsAirConfHsuName RW_ | HSU name. winlink1OO0HbsAirConfHsuType RO | HSU type (1 = Fixed 2 = Stationary 3 = Mobile 4= Transport 5 = Mobile_co_channel 6 = Residential 7 = N_Fixed 8 =N_Residential) winlink1O00HbsAirConflndex RO | HSUs configuration table index. winlink1O0OHbsAirConfLanPortsConn RW _ | Indicates if the connection between LAN 1 and LAN ection 2 is enabled. 1- Enabled 2- Disabled. winlink1O00HbsAirConfMacAddress RO | HSU MAC Address. winlink1OOOHbsAirConfNumOfResour RW_ | Number of DownLink Resources which are allocated cesDL to specific HSU. winlink1OOOHbsAirConfNumOfResour RW_ | Number of UpLink Resources which are allocated to

specific HSU.

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 10

HBS

Table 8: HBS Private MIB Parameters (Sheet 3 of 43)

MIB Parameters

Name OID Type 3 Description oO [s 4 winlink1OOOHbsAirConfNumOfTs RW_ | Number of time slot which are allocated to specific HSU. winlink1OOOHbsAirConfNumOfTsUp RW_ | Number of UL time slot which are allocated to specific HSU. winlink1000HbsAirConfResourceType RW_ | Resources Allocation Type (AA or BE) to specific HSU. winlink1000HbsAirConfServiceCatego RO | Indicates Service Category received from Radius ry server values can be from 1 to 8 0 - undefined winlink1O00HbsAirConfTable N/A | Holds the table for all registered HSUs in the sector (21 entries). winlink1OOOHbsAirConfUpMir RW_ | Uplink MIR towards specific HSU in units of kbps. winlink1OOOHbsAirCpeCapacityLimit RO | Capacity Limit in Kilo bit per second. winlink1OOOHbsAirDelayVsTputOpt RW _ | Delay vs. Throughput optimization type: 1 = Delay sensitivity 2 = Throughput optimized winlink1OOOHbsAirDowntTraffickbps RO | Average data throughput (expressed in Kbps) transmitted in the DL towards all the SUs during the last second. winlink1OO0O0HbsAirDownUtil Mill RO_ | Sector Air Interface utilization in the Downlink direction (thousandths). Average time percentage out of the entire BTS DL capability that was used for transmitting data to all the SUs. winlink1OOOHbsAirGeoAzimuth RW_ | Geographic sector azimuth in degrees * 10. winlink1O0OHbsAirGeoBeamwidth RW_ | Geographic sector beamwidth in degrees * 10. winlink1O0OHbsAirHbsType RO_ | HBSs Service Type Category winlink1OOOHbsAirHsulnBytes RO | Number of frames received in the HSU Lan port. winlink1OOOHbsAirHsulnFrames RO | Number of bytes received in the HSU Lan port. winlink1OOOHbsAirHsuMacAddress RO | HSU MAC Address. winlink1OOOHbsAirHsuOutBytes RO | Number of frames transmitted from the HSU Lan port. winlink1OOOHbsAirHsuOutFrames RO | Number of bytes transmitted from the HSU Lan port. winlink1OOOHbsAirHsuRxRatelnFps RO | HSU Tx Rate in Fps. winlink1OOOHbsAirHsuRxRatelnKbps RO | HSU Rx Rate in Kbps. winlink1OOOHbsAirHsuTxRatelnFps RO | HSU Tx Rate in Fps. winlink1OOOHbsAirHsuTxRatelnKbps RO | HSU Tx Rate in Kbps. winlink1OOOHbsAirLink1588TCPerfor RO | TC performance. mance winlink1OOOHbsAirLinkAntennaType RO | HSU External Antenna Type: Monopolar or Bipolar. winlink1OOOHbsAirLinkBsaAzimuth RO | Absolute (geographical) azimuth of the HSU (looking

from HBS site).

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 11

HBS

Table 8: HBS Private MIB Parameters (Sheet 4 of 43)

MIB Parameters

Name

OID

Type

Description

winlink1OOOHbsAirLinkCompressedM on

3 | Access

Holds all the link information in compressed binary (Bytes/octets). Fields included (size in bytes): Link State(1) Link Working Mode(1) Session Id(4) HBS Est. Tput(4) HSU Est. Tput(4) HBS Rss(1) HBS Rss Balance(1) HSU Rss(1) HSU Rss Balance(1) Tx Operation Mode(1) HSU In Bytes(4) HSU Out Bytes(4) HSU In Frames(4) HSU Out Frames(4) HSU ID (1 bytes) HSU Rx Rate In Kbps (4) HSU Tx Rate In Kbps (4) HSU Rx Rate In Fps (4) HSU Tx Rate In Fps (4) Peak throughput in the DL direction (4) Peak throughput in the UL direction (4) Number of local changes at HSU(1) Alignment Status(1) HBS Chain 1 Rss(1) HBS Chain 2 Rss(1) HBS Chain 3 Rss(1) HSU Chain 1 Rss(1) HSU Chain 2 Rss(1) HSU Chain 3 Rss(1) HSU Current Rate Index (2 bytes) HSU Current Rate CBW (1 bytes) HSU Current Rate GI (1 bytes) HBS Current Rate Index (2 bytes) HBS Current Rate CBW (1 bytes) HBS Current Rate GI (1 bytes) Bsa Azimuth(2) HSU LAN 1 Rx Rate In Kbps (4) HSU LAN 1 Tx Rate In Kbps (4) HSU LAN 1 Rx Rate In Fps (4) HSU LAN 1 Tx Rate In Fps (4) HSU LAN 2 Rx Rate In Kbps (4) HSU LAN 2 Tx Rate In Kbps (4) HSU LAN 2 Rx Rate In Fps (4) HSU LAN 2 Tx Rate In Fps (4) 1588TC Performance(1) SyncE Performance(1) ATPC status (1) HBS Speed(4)

HSU Speed(4) Reserved(8) IGMP MG Per CPE(2)

winlink1OOOHbsAirLinkCompressedSt atic

RO

Holds all the configuration data of this link in compressed format. Helps the NMS to get info regarding new Unregistered links. Fields Included: SessionID (4 bytes) HSU IP address (4 bytes) HSU Name (32 bytes) HSU Location (32 bytes) HSU Serial number (16 bytes) HSU MAC Address (12 bytes) Air Link Range Max Throughput Down (4 bytes) Max Throughput Up. (4 bytes) Cpacity Limit (4 bytes) HSU Antenna type (1 byte) Aggregate Capacity (4 bytes) 1588TC supported (1 byte) SyncE supported (1 byte)

winlink1OOOHbsAirLinkEntry

N/A

Link table entry. INDEX { winlink1000HbsAirLinkIndex }

winlink1OOOHbsAirLinkHbsEstTput

RO

Holds the Estimated throughput from the HBS to the HSU.

winlink1OOOHbsAirLinkHbsRss

RO

Holds the RSS of specific link (HBS side).

winlink1OOOHbsAirLinkHbsRssBal

RO

Holds the RSS Balance of specific link (HBS side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0: Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS.

winlink1OOOHbsAirLinkHsuEstTput

RO

Holds the Estimated throughput from the HSU to the HBS.

winlink1OOOHbsAirLinkHsuld

RO

HSU ID of specific link (if registered). Unregistered links have -1.

winlink1OOOHbsAirLinkHsuRss

RO

Holds the RSS of specific link (HSU side).

winlink1OOOHbsAirLinkHsuRssBal

RO

Holds the RSS Balance of specific link (HSU side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0: Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS.

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 12

HBS

Table 8: HBS Private MIB Parameters (Sheet 5 of 43)

MIB Parameters

nnaType

Name OID Type 3 Description oO S) 4 winlink1OOOHbsAirLinkHsuSerial RO | Holds the serial number for specific HSU. winlink1OOOHbsAirLinkIndex RO | HSUs configuration table index. winlink1OOOHbsAirLinkNumOfLinks RO | Number of links in the links table. winlink1OOOHbsAirLinkPeakTputDown RO | Peak throughput in the DL direction (kbps). winlink1OOOHbsAirLinkPeakTputUp RO | Peak throughput in the UL direction (kbps). winlink1OOOHbsAirLinkRange RO | Holds the range of specific link. winlink1000HbsAirLinkSessionld RO | Holds the Session ID of the link. winlink1OOOHbsAirLinkState RO | Holds the state of specific link. winlink1OOOHbsAirLinkSyncEPerforma RO | SyncE performance. nce winlink1O000HbsAirLinkTable N/A | Holds the table for all links in the sector. winlink1OOOHbsAirLinkTxOperMode RO | Holds the TX operation mode. winlink1OOOHbsAirLinkUtilCompresse RO | One string that holds the 6 Utilization per link dMon values: DownSecRel (2 bytes) UpSecRel (2 bytes) DownAllocRel (4 bytes) UpAllocRel (4 bytes) DowntTraffic (4 bytes) UpTraffic (4 bytes). winlink1OOOHbsAirLinkUtiIDownAlloc RO | The time percentage (in thousandths) relative to RelMill the SU DLallocation that was used for transmitting data to the SU. winlink1OOOHbsAirLinkUtiIDownSecR RO | The average time percentage (in thousandths) out elMill of the BTS DL capability that was used for transmitting data to the SU. winlink1OOOHbsAirLinkUtilDownTraffi RO | Average data throughput (Exported in Kbps) cKbps transmitted in the DL towards the SU during the last second. winlink1OOOHbsAirLinkUtilUpAllocRel RO | The time percentage (in thousandths) relative to Mill the SU ULallocation that was used for receiving data from the SU. winlink1OOOHbsAirLinkUtilUpSecRelM RO | The average time percentage (in thousandths) out ill of the BTS UL capability that was used for receiving data from the SU winlink1OOOHbsAirLinkUtilUpTraffickKb RO | Average data throughput (Exported in Kbps) ps received in the UL from the SU during the last second. winlink1OOOHbsAirLinkWorkingMode RO | Indicates the sub-state within the version compatibility. winlink1OOOHbsAirMaxDistanceMete RW_ | Maximum distance in meters. Used by Mobility links rsMobility only. winlink1OOOHbsAirMaxTputDown RO | Max Throughput Downlink. winlink1OOOHbsAirMaxTputUp RO | Max Throughput Uplink. winlink1OOOHbsAirMinimalTimeBetw RW_ | Minimal time in seconds between two Automatic eenAutoRealignment Realignment Processes winlink1OOOHbsAirMobilityAzTrack RO | Azimuth tracking for mobility status: 1= Not applicable 2 = Active 3 =Impossible winlink1OOOHbsAirNumberOfRegister RO | Number of registered active HSUs. edActiveCpes winlink1OOOHbsAirNumberOfRegister RO | Number of registered HSUs. edCpes winlink1OOOHbsAirOpMode RW_ | Holds the operation mode of the HBS. winlink1OOOHbsAirRegisteredCpe158 RO | TC performance. 8TCPerformance winlink1O00HbsAirRegisteredCpeAnte RO | HSU External Antenna Type: Monopolar or Bipolar.

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 13

HBS

Table 8: HBS Private MIB Parameters (Sheet 6 of 43)

MIB Parameters

Name

OID

Type

Description

winlink1000HbsAirRegisteredCpeBsa Azimuth

3 | Access

Absolute (geographical) azimuth of the HSU (looking from HBS site).

winlink1OOOHbsAirRegisteredCpeCom pressedMon

Holds all the link information in compressed binary (Bytes/octets). Fields included (size in bytes): Link State(1) Link Working Mode(1) Session Id(4) HBS Est. Tput(4) HSU Est. Tput(4) HBS Rss(1) HBS Rss Balance(1) HSU Rss(1) HSU Rss Balance(1) Tx Operation Mode(1) HSU In Bytes(4) HSU Out Bytes(4) HSU In Frames(4) HSU Out Frames(4) HSU ID (1 bytes) HSU Rx Rate In Kbps (4) HSU Tx Rate In Kbps (4) HSU Rx Rate In Fps (4) HSU Tx Rate In Fps (4) Peak throughput in the DL direction (4) Peak throughput in the UL direction (4) Number of local changes at HSU(1) Alignment Status(1) HBS Chain 1 Rss(1) HBS Chain 2 Rss(1) HBS Chain 3 Rss(1) HSU Chain 1 Rss(1) HSU Chain 2 Rss(1) HSU Chain 3 Rss(1) HSU Current Rate Index (2 bytes) HSU Current Rate CBW (1 bytes) HSU Current Rate GI (1 bytes) HBS Current Rate Index (2 bytes) HBS Current Rate CBW (1 bytes) HBS Current Rate GI (1 bytes) Bsa Azimuth(2) HSU LAN 1 Rx Rate In Kbps (4) HSU LAN 1 Tx Rate In Kbps (4) HSU LAN 1 Rx Rate In Fps (4) HSU LAN 1 Tx Rate In Fps (4) HSU LAN 2 Rx Rate In Kbps (4) HSU LAN 2 Tx Rate In Kbps (4) HSU LAN 2 Rx Rate In Fps (4) HSU LAN 2 Tx Rate In Fps (4) 1588TC Performance(1) SyncE Performance(1) ATPC status (1) HBS Speed(4)

HSU Speed(4) IGMP MG Per CPE(2) Reserved(1)

winlink1O000HbsAirRegisteredCpeCom pressedStatic

RO

Holds all the configuration data of this link in compressed format. Helps the NMS to get info regarding new Unregistered links. Fields Included: Session|D (4 bytes) HSU IP address (4 bytes) HSU Name (32 bytes) HSU Location (32 bytes) HSU Serial number (16 bytes) HSU MAC Address (12 bytes) Air Link Range Max Throughput Down (4 bytes) Max Throughput Up. (4 bytes) Cpacity Limit (4 bytes) HSU Antenna type (1 byte) Aggregate Capacity (4 bytes) 1588TC supported (1 byte) SyncE supported (1 byte)

winlink1000HbsAirRegisteredCpeCpe CapacityLimit

RO

Capacity Limit in Kilo bit per second.

winlink1O00HbsAirRegisteredCpeHbs EstTput

RO

Holds the Estimated throughput from the HBS to the HSU.

winlink1OOOHbsAirRegisteredCpeHbs

RO

Holds the RSS of specific link (HBS side).

winlink1OOOHbsAirRegisteredCpeHbs RssBal

RO

Holds the RSS Balance of specific link (HBS side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0: Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS.

winlink1O00HbsAirRegisteredCpeHsu EstTput

RO

Holds the Estimated throughput from the HSU to the HBS.

winlink1O000HbsAirRegisteredCpeHsul

RO

HSU ID of specific link (if registered). Unregistered links have -1.

winlink1000HbsAirRegisteredCpeHsul nBytes

RO

Number of frames received in the HSU Lan port.

winlink1O00HbsAirRegisteredCpeHsul nFrames

RO

Number of bytes received in the HSU Lan port.

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 14

HBS

Table 8: HBS Private MIB Parameters (Sheet 7 of 43)

MIB Parameters

perMode

Name OID Type B Description o °o 4 winlink1OOOHbsAirRegisteredCpeHsu RO | HSU MAC Address. MacAddress winlink1OOOHbsAirRegisteredCpeHsu RO | Number of frames transmitted from the HSU Lan OutBytes port. winlink1OOOHbsAirRegisteredCpeHsu RO | Number of bytes transmitted from the HSU Lan OutFrames port. winlink1OOOHbsAirRegisteredCpeHsu RO | Holds the RSS of specific link (HSU side). Rss winlink1OOOHbsAirRegisteredCpeHsu RO | Holds the RSS Balance of specific link (HSU side). -2 RssBal : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0: Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS. winlink1O000HbsAirRegisteredCpeHsu RO | HSU Tx Rate in Fps. RxRatelnFps winlink1O00HbsAirRegisteredCpeHsu RO | HSU Rx Rate in Kbps. RxRatelnKbps winlink1OOOHbsAirRegisteredCpeHsu RO | Holds the serial number for specific HSU. Serial winlink1O00HbsAirRegisteredCpeHsu RO | HSU Tx Rate in Fps. TxRatelnFps winlink1OOOHbsAirRegisteredCpeHsu RO | HSU Tx Rate in Kbps. TxRatelnKbps winlink1O00OHbsAirRegisteredCpelpAd RO | HSU IP Address dress winlink1O0OHbsAirRegisteredCpelpAd RO | HSU IP Address V6 dressV6 winlink1000HbsAirRegisteredCpeMax RO | Max Throughput Downlink. TputDown winlink1O0OHbsAirRegisteredCpeMax RO | Max Throughput Uplink. TputUp winlink1000HbsAirRegisteredCpePeak RO | Peak throughput in the DL direction (kbps). TputDown winlink1O00HbsAirRegisteredCpePeak RO | Peak throughput in the UL direction (kbps). TputUp winlink1O00HbsAirRegisteredCpeProd RO | HSU Product Name uctName winlink1000HbsAirRegisteredCpeRan RO | Holds the range of specific link. ge winlink1O00HbsAirRegisteredCpeSess RO | Holds the Session ID of the link. ionld winlink1O0OHbsAirRegisteredCpeStat RO | Holds the state of specific link. e winlink1OOOHbsAirRegisteredCpeSync RO | SyncE performance. EPerformance winlink1OOOHbsAirRegisteredCpeTabl N/A | Holds the table for all CPEs in the sector. e winlink1OOOHbsAirRegisteredCpeTabl N/A |Link table entry. INDEX { eEntry winlink1OOOHbsAirRegisteredCpeTablelndex } winlink1OOOHbsAirRegisteredCpeTabl RO | HSUs configuration table index. elndex winlink1O00HbsAirRegisteredCpeTxO RO | Holds the TX operation mode.

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 15

HBS

Table 8: HBS Private MIB Parameters (Sheet 8 of 43)

MIB Parameters

ate

Name OID Type 3 Description oO s 4 winlink1O000HbsAirRegisteredCpeUtil RO | One string that holds the 6 Utilization per link CompressedMon values: DownSecRel (2 bytes) UpSecRel (2 bytes) DownAllocRel (4 bytes) UpAllocRel (4 bytes) DowntTraffic (4 bytes) UpTraffic (4 bytes). winlink1OO0O0HbsAirRegisteredCpeUtil RO | The time percentage (in thousandths) relative to DownAllocRelMill the SU DLallocation that was used for transmitting data to the SU. winlink1O00HbsAirRegisteredCpeuUtil RO_ | The average time percentage (in thousandths) out DownSecRelMiill of the BTS DL capability that was used for transmitting data to the SU. winlink1O00HbsAirRegisteredCpeUti RO_ | Average data throughput (Exported in Kbps) DowntTraffickKbps transmitted in the DL towards the SU during the last second. winlink1O000HbsAirRegisteredCpeUti RO | The time percentage (in thousandths) relative to UpAllocRelMill the SU ULallocation that was used for receiving data from the SU. winlink1O000HbsAirRegisteredCpeUti RO | The average time percentage (in thousandths) out UpSecRelMill of the BTS UL capability that was used for receiving data from the SU. winlink1O00HbsAirRegisteredCpeUti RO | Average data throughput (Exported in Kbps) UpTrafficKbps received in the UL from the SU during the last second. winlink1O00HbsAirRegisteredCpeWor RO | Indicates the sub-state within the version kingMode compatibility. winlink1OOOHbsAirSectorCbwSupport RO | Represents the channel bandwidth which is edStr supported by the HBS and all connected HSUs. winlink1OOOHbsAirSingleHsuMode RW | Single HSU mode: 1=NotApplicable 2 = Single HSU 3= Multiple HSUs winlink1O00HbsAirState RO | Holds the state of the HBS. winlink1OOOHbsAirSyncEPerformance RO | SyncE performance when HBS is not reference clock winlink1OOOHbsAirTimeSlotAllocation RW_ | Time Slots Allocation Bitmap for the entire sector Bitmap (Hex Value). winlinkLOOOHbsAirUCBPMinCS RW_ | Minimal contention slot length used for UCBP algorithm (in ms.) between 5-20ms. winlink1OOOHbsAirUCBPSharingPerce RW_ | Sharing percentage used by UCBP algorithm (15-75) ntage winlink1OO0OHbsAirUpTraffickKbps RO_ | Average data throughput (expressed in Kbps) received in the UL from all the SUs during the last second. winlink1OOOHbsAirUpUtil Mill RO | Sector Air Interface utilization in the Uplink direction (thousandths). The average number of timeslots that were used in the UL (by all the links) out of the entire number of timeslots. winlink1OOOHbsBridgeAgingTime RW_ | Timeout in seconds for aging. winlink1OOOHbsBridgeEntireRestrictio RW _| Byte array that contains entire Restriction table nTable winlink1OOOHbsBridgeFloodOverload RW_ | Flood overload protection 1- Enabled 2- Disabled. Protect winlink1OOOHbsBridgeMembershipEn N/A | HBS bridge membership table entry. INDEX { try winlink1OOOHbsBridgeMembershipIndex } winlink1OOOHbsBridgeMembershipIn RO | HBS bridge membership table index. dex winlink1OOOHbsBridgeMembershipSt RW_ | HBS bridge membership state bitmap. Each bit

represents Blocked/Opened relation (membership) between two HSUs. Blocked=0 (bit) Opened=1 (bit). This object holds the relation to first 32 HSUs.

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 16

HBS

Table 8: HBS Private MIB Parameters (Sheet 9 of 43)

MIB Parameters

ble

Name OID Type B Description oO s 4 winlink1OOOHbsBridgeMembershipSt RW_ | HBS bridge membership state bitmap. Each bit ate2nd represents Blocked/Opened relation (membership) between HSU and LAN/Stack port of the HBS. Blocked=0 (bit) Opened=1 (bit). Only 2 bits are used. winlink1OOOHbsBridgeMembershipSt RW_ | HBS bridge membership state bitmap. Each bit ate3rd represents Blocked/Opened relation (membership) between two HSUs. Blocked=0 (bit) Opened=1 (bit). This object holds the relation to last 32 HSUs. winlink1OOOHbsBridgeMembershipTa N/A | Holds the bridge membership relations for all the ble registered HSUs. winlink1OOOHbsBridgeVlanDefaultld RW_ | HBS bridge Vlan default id. winlink1OOOHbsBridgeVlanDoubleTag RW_ | HBS bridge Vian double tag. winlink1OOOHbsBridgeVlanEgress RW_ | HBS bridge Vlan egress. winlink1OOOHbsBridgeVlanEntry N/A | HBS bridge Vlan table entry. INDEX { winlink1OOOHbsBridgeVlanIndex } winlink1OOOHbsBridgeVlanFilterIn RW_ | HBS bridge Vlan filter in. winlink1OOOHbsBridgeVlanFilterOut RW_ | HBS bridge Vlan filter out. winlink1OOOHbsBridgeVlanIndex RO | HBS bridge Vlan table index. winlink1OOOHbsBridgeVlanIngress RW_ | HBS bridge Vlan ingress. winlink1OO0OHbsBridgeVlanTable N/A | Holds the bridge Vlan operations towards all the registered HSUs. winlink1000HbsPerfMonAirGenCurrA RO | The number of seconds in which RPL Ethernet ctiveSeconds swervice was not blocked in the present 15 minutes period. winlink1000HbsPerfMonAirGenCurrE N/A _| This is an entry in the Current Interval Table. INDEX ntry {iflndex } winlink1000HbsPerfMonAirGenCurrE RO | The number of times throughput was below thCapacityThreshUnder threshold in the present 15 minutes period. Relevant for point to point systems. winlink1000HbsPerfMonAirGenCurrH RO | The number of times actual traffic was above ighTrafficThreshExceed threshold in the present 15 minutes period. winlink1000HbsPerfMonAirGenCurrR RO | Current RX Mega Bytes starting from the present 15 xMBytes minutes period. (Represents the LAN traffic RX direction toward the HSU) winlink1000HbsPerfMonAirGenCurrT N/A | This table defines/keeps the ethernet counters of able the current 15 min interval. winlink1000HbsPerfMonAirGenCurrT RO | Current Transmit Mega Bytes starting from the xMBytes present 15 minutes period. (Represents the LAN traffic TX direction from the HSU) winlink1000HbsPerfMonAirGenDayAc RO | The number of seconds in which RPL Ethernet tiveSeconds service was not blocked each day. winlink1000HbsPerfMonAirGenDayE N/A | This is an entry in the Days Table. INDEX {iflndex ntry winlink1OOOHbsPerfMonAirGenDayldx } winlink1000HbsPerfMonAirGenDayEt RO | The number of times throughput was below hCapacityThreshUnder threshold each day. Relevant for point to point systems. winlink1000HbsPerfMonAirGenDayHi RO | The number of times actual traffic was above ghTrafficThreshExceed threshold each day. winlink1000HbsPerfMonAirGenDayld RO | This table is indexed per Day number. Each interval x is of 15 minutes and the oldest is 96. winlink1000HbsPerfMonAirGenDayRx RO | Current RX Mega Bytes per day. (Represents the MBytes LAN traffic RX direction toward the HSU) winlink1000HbsPerfMonAirGenDayTa N/A | This table defines/keeps the ethernet counters of

the last month (in resolution of days).

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 17

HBS

Table 8: HBS Private MIB Parameters (Sheet 10 of 43)

MIB Parameters

ownQueMir

Name OID Type 3 Description oO °o 4 winlink1000HbsPerfMonAirGenDayTx RO | Current Transmit Mega Bytes per day. (Represents MBytes the LAN traffic TX direction from the HSU) winlink1000HbsPerfMonAirGenInterv RO | The number of seconds in which RPL Ethernet alActiveSeconds service was not blocked in the each interval. winlink1000HbsPerfMonAirGenInterv N/A | This is an entry in the Interval Table. INDEX {iflndex alEntry winlink1O0O0HbsPerfMonAirGenIntervalldx } winlink1000HbsPerfMonAirGenInterv RO | The number of times throughput was below alEthCapacityThreshUnder threshold in the each interval. Relevant for point to point systems. winlink1000HbsPerfMonAirGeninterv RO | The number of times actual traffic was above alHighTrafficThreshExceed threshold in the each interval. winlink1000HbsPerfMonAirGenInterv RO | This table is indexed per interval number. Each alldx interval is of 15 minutes and the oldest is 96. winlink1000HbsPerfMonAirGenInterv RO | Current RX Mega Bytes per interval. (Represents alRxMBytes the LAN traffic RX direction toward the HSU). winlink1000HbsPerfMonAirGenInterv N/A | This table defines/keeps the ethernet counters of alTable the last day (in resolution of 15 min intervals). winlink1000HbsPerfMonAirGenInterv RO | Current Transmit Mega Bytes per interval. alTxMBytes (Represents the LAN traffic TX direction from the HSU) winlink1OOOHbsPerfMonBBERThresh RW_ | HBS performance monitor BBER threshold. 1 winlink1000HbsPerfMonEstThroughp RW_ | HBS performance monitor estimated throughput utThreshKbps Threshold. winlink1000HbsPerfMonHightrafficTh RW_ | HBS performance monitor high traffic threshold. reshKbps winlink1O0OHbsPerfMonRxThresh1 RW_ | HBS performance monitor receive power threshold 1: winlink1OOOHbsPerfMonRxThresh2 RW_ | HBS performance monitor receive power threshold 2; winlink1000HbsPerfMonThreshEntry N/A | HBS performance monitor threshold table entry. INDEX { winlink1000HbsPerfMonThreshindex } winlink1000HbsPerfMonThreshIndex RO | HBS performance monitor threshold table index. winlink1000HbsPerfMonThreshTable N/A | Holds the performance monitor thresholds towards all the registered HSUs. winlink1000HbsPerfMonTxThresh1 RW_ | HBS performance monitor transmit power threshold. winlink1000HbsServiceCategoryDelay RW_ | Delay Sensitivity to specific HSU. Sensitivity winlink1000HbsServiceCategoryDhcp RW_ | DHCP filtering to specific HSU. Filter winlink1000HbsServiceCategoryDLMi RW | Service Category Downlink MIR F winlink1000HbsServiceCategoryDLRe RW_ | Service Category Downlink Resources sources winlink1000HbsServiceCategoryEntry N/A | HBS service Radius Service Category table entry. INDEX { winlink1000HbsServiceCategorylndex } winlink1000HbsServiceCategorylndex RW_ | Service Category Index winlink1000HbsServiceCategoryNam RW_ | Service Category Name e winlink1000HbsServiceCategoryPppo RW_ | PPPoE filtering to specific HSU. eFilter winlink1000HbsServiceCategoryQoSD RW _ | Private MIR for each QoS group of the Downlink

direction (4 values separated by comma).

RADWIN Broadband Wireless Products MIB Reference

Release 4.9.35 Page 18

HBS

Table 8: HBS Private MIB Parameters (Sheet 11 of 43)

MIB Parameters

gRobustnesVariable

Name OID Type 3 Description oO ° 4 winlink1000HbsServiceCategoryQoSD RW_ | Weight in percent for each QoS group of the ownQueWeight Downlink direction (4 values separated by comma). winlink1000HbsServiceCategoryQoSD RW_ | Strict QOS Boolean indication for each QOS group of ownsStrict the Downlink direction (4 values separated by comma). winlink1000HbsServiceCategoryQoSD RW_ | TTLin mili second for each QoS group of the ownTtlIMs Downlink direction (4 values separated by comma). winlink1000HbsServiceCategoryQoSU RW_ | Private MIR for each QoS group of the Uplink pQueMir direction (4 values separated by comma). winlink1000HbsServiceCategoryQoSU RW_ | Weight in percent for each QoS group of the Uplink pQueWeight direction (4 values separated by comma). winlink1000HbsServiceCategoryQoSU RW _ | Strict QOS Boolean indication for each QOS group of pStrict the Uplink direction (4 values separated by comma). winlink1000HbsServiceCategoryQoSU RW_ | TTLin mili second for each QoS group of the Uplink pTtIMs direction (4 values separated by comma). winlink1000HbsServiceCategoryQoSV RW_ | VoIP supported to specific HSU. olPState winlink1000HbsServiceCategoryReso RW_| Resources Allocation Type (AA or BE) to specific urceType HSU. winlink1000HbsServiceCategoryTable N/A | Holds the Radius Service Category profiles winlink1000HbsServiceCategoryULMi RW_ | Service Category Uplink MIR r winlink1000HbsServiceCategoryULRe RW_ | Service Category Uplink Resources sources winlink1000HbsServiceCommandStr RW _ | Ability to perform special command in the HBS. Format (string): Operation Index Session Param1 Param2....| ParamN The index and Session|ID can be uniting to one parameter. On registered HSU it is HSU-ID and on Unregistered it is Session-ID. winlink1000HbsServiceDhcpFilter RW_ | Dhcp Filter winlink1000HbsServicedotXEnable RW_ | Enables/Disables 802.1x Authentication 1 - Mandatory Disabled 2 - disable 3- enable winlink1000HbsServicedot